YYC-2S 5V 1 Channel Relay Module Cycle Trigger Delay Power-off Delay Timing Circuit Timer Switch with Display


Isaiah 55:8-9 John 3:16 Philippians 4:19
Please select: Voltage 24V
Price:
Sale priceR 443.80
Stock:
Sold out
 
 

We offer a 7 day replacement guarantee on all items that arrive defective or damaged. View our full policy here.

 

All payment methods are fully secure via SSL. We have the following payment methods available: Credit & Cheque Card; Instant EFT; QR Code Apps; Debit Card; MobiCred; and SCode.

 

Description

The YYC-2S 5V 1 Channel Relay Module is perfect for a variety of applications that require controlling solenoid valves, pumps, motors, light strips, etc.

With an output power of 5A, this relay module can control both DC and AC loads.

Additionally, the time range is adjustable from 0.01 seconds to 999 minutes, making it versatile and convenient to use.






More Information:


Specifications:
 
1.24 kinds of commonly used functions to meet more application requirements; can control solenoid valves, pumps, motors, light strips, etc.
2: Output power: can control DC or AC load within 5A
3: Time range: 0.01 seconds to 999 minutes adjustable at any time
4: Description of the wiring port:
1, DC: input DC power supply positive
2, DC-: input DC power supply negative
3, IN: signal input positive
4, IN-: signal input terminal
5, NO: Relay normally open interface, the relay is suspended before the suction, after the suction and short circuit with COM
6, COM: relay common interface
7. NC: The relay normally closes the interface, and the relay is shorted to COM before the suction is closed.
Button trigger: (positive trigger: DC- and in- short circuit, DC and IN button
Or: (negative trigger: DC and in short circuit, DC- and IN- button)

Button Setting Instructions:
 
- Power on display "————" means to enter standby mode;
- Press K1 for the first time (it takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjusts the main mode, K3K4 adjustment function
- Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit)
- Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit)
- Pressing K1 for the fourth time, “————” means to enter standby mode
- Press K4 in standby mode to permanently turn off/on the display and switch the low power mode
 
Decimal Time Unit Description:
 
- X.XX decimal point in hundred, timing range: 0.01 seconds to 9.99 seconds
- XX.X decimal point in ten, timing range: 0.1 seconds to 99.9 seconds
- XXX has no decimal point, timing range: 1 second to 999 seconds
- XXX. The decimal point is in one place, the time range is from 1 minute to 999 minutes.

Function List:
 
P-11: Jog (give the signal relay, the signal disappears and the relay stops)
P-12: Self-locking (send a signal relay to pull in, then give a signal relay to stop)
P-13: Give the signal, the relay will stop automatically for A seconds; the trigger will be invalid during the delay.
P-14: Give the signal, the relay will stop automatically for A seconds; trigger the retime during the delay.
P-15: Give the signal, the relay will stop automatically for A seconds; trigger the superimposed timing during the delay.
P-16: Give signal, the relay will stop automatically for A seconds; trigger reset during delay
P-17: Give the signal, the relay is closed, the input signal is disconnected, the power is turned off after A seconds, and the signal is kept output again during the delay.
P-18: After power-on, the relay will immediately pull in, after a delay of A seconds, the power will be turned off;
P-21: Give the signal, after a delay of A seconds, the relay pulls in
P-22: Give signal, after more than A seconds, the relay pulls in, the signal disappears, the relay stops.
P-23: After the signal disappears for more than A seconds, the relay is closed, there is a signal, and the relay stops.
P-24: There is a signal. After more than A seconds, the relay is closed. After the signal disappears for more than A seconds, the relay stops.
P-25: There is a signal after more than A seconds, the relay is closed, and after a signal exceeds A seconds, the relay stops.
P-26: There is a signal. The relay stops after A seconds of suction. The signal disappears and the relay stops again for A seconds.
P-27: The pulse signal is detected, the relay stops; if there is no pulse signal, the relay delays for A seconds; (the signal is continuous or the signal disappears as no pulse signal)
P-28: After power-on, after a delay of A seconds, the relay pulls in until the power is turned off.
P-31: After power-on, the relay is closed for A seconds, disconnected for B seconds, infinite loop;
P-32: Signal, start P-31 infinite loop; signal disappears, terminate loop
P-33: Give a signal, start P-31 infinite loop; give another signal to terminate the loop
P-34: After power-on, after a delay of A seconds, the relay pulls in and closes after B seconds.
P-35: There is a signal. After a delay of A seconds, the relay pulls in and closes after B seconds.
P-36: There is a signal. After more than A seconds, the relay pulls in, the B is stopped after B seconds, the signal disappears, and the timing is cleared.
P-37: There is a signal, the relay will stop automatically for A seconds, and then stop for 24 seconds. The signal trigger is invalid during A B time.
P-38: There is a signal, the relay will stop automatically for A seconds, stop and re-clock for B seconds, and then automatically close for A seconds.
P-41: There is no signal; the signal disappears; the relay works after the delay of A time.
P-42: The signal disappears, after a delay of A time, the relay works; the end of work B time
P-43: The signal disappears. After the A time, the relay works; the working B time ends.
P-44: After power-on, the relay works for A time and stops B time; the cycle stops automatically for C times.
P-45: The power is not activated, after the signal is given; the relay works for A time, the B time is stopped; the cycle C stops automatically; the signal is given again, once again
P-46: After the signal is sent for more than A times, the relay is closed; the suction is kept; the power is stopped.
P-47: After the signal is sent for more than A times, the relay is closed for B seconds.
P-48: In C seconds, after the signal is continuously sent for more than A times, the relay is closed for B seconds.
 
Package Included:

1 x YYC-2S 5V 1 Channel Relay Module Cycle Trigger Delay Power-off Delay Timing Relay